QEQI Q39
A compact electronic water treatment unit for suitable residential and small commercial pipework. Start with the pipe size and installation conditions.
View productSelect the appropriate configuration around the equipment feed and system conditions, with maintenance and leak inspection in mind.
Evaluate the feed, equipment and installation limits.
Record the baseline and compare equivalent operating conditions over an agreed period.
Existing scale removal can expose old leaks. Follow equipment requirements and retain required feed-water treatment.
A useful project record includes equipment configuration, operating baseline and the agreed monitoring period.
Practical considerations for this application, its existing treatment and performance review.
Building size helps describe demand, but selection starts with the installation pipe and connected equipment. Check outside diameter, branches, temperature, circulation and heating capacity. Q39's 38.1 mm OD limit should not be interpreted as a rating for a particular number of rooms or bathrooms.
Include the cold feed, heater, return loop and branches in the pipework review. Confirm the proposed installation point against the model instructions and inspect metal connections for closed electrical loops. A domestic installation example should not be applied automatically to a large recirculating system.
Continue the temperature management, flushing, inspection and microbial controls required for the building. Scale control is assessed against deposits and equipment operation; it is not a demonstration of potable-water safety or a substitute for a water-hygiene programme.
A useful configuration connects product ratings to the actual operating environment.
| Assessment area | Site information | Engineering decision |
|---|---|---|
| Pipework & connectivity | Outside / nominal diameter, material, branches and closed electrical loops | Model fit, clearance and signal conditions |
| Hydraulic conditions | Flow, circulation path, pump position and available pressure | Installation location and filtration configuration |
| Water & process | Hardness, suspended solids, temperature and existing treatment | Treatment roles and processes to retain |
| Operation & maintenance | Load profile, cleaning history, inspection and discharge access | Comparable baseline and practical service access |
Electronic scale control, particle separation and water-quality compliance are separate responsibilities. A site may need several coordinated processes. Neither scale control nor filtration universally replaces softening, membrane treatment, disinfection or chemical management.
Record equipment, deposits, cleaning intervals and existing water-treatment practice before changes.
Record load, flow, temperature, water quality and any parallel process changes during the observation period.
Compare cleaning records, pressure drop, heat-transfer behaviour or solids collection as appropriate to the application.
Separate measured results, operator observations and financial estimates. Do not assume every change comes from one device.